Power Distribution Cables
600/1000V multiconductor Type T/N control cables
Construction
Conductor:Stranded copper conductor tin or alloy coated where necessary for the application , conductor per
ASTM or IEC 60228.
Separator tape: optional
Insulation: Polyvinylchloride(PVC)/nylon according to IEEE 1580 2010 Type T/N,Type X, E, T, S, P, LSX and LSE
as option.
Shielding: optional
Jacket: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P or
TPO jacket as option (optional for Type P with HD thicknesses).
Armor: optional and shall be nonmagnetic
Sheath: Thermosetting Polychloroprene(neoprene) according to IEEE 1580 2010 Type N, Type T, CP, CPE, L, P
or TPO sheath as option (optional except for tinned copper braid armoured cables).
Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO
jacket/sheath.
Table B.9—Typical dimensions and weights; multiconductor control 600/1000 V; Type T/N cables
Number of conductors |
Conductor AWG size |
Unarmored | Armored | Armored and sheathed | |||
---|---|---|---|---|---|---|---|
Nom. dia. (in) | Approx. weight (lb/1000 ft) | Nom. dia. (in) | Approx. weight (lb/1000 ft) | Nom. dia. (in) | Approx. weight (lb/1000 ft) | ||
2 | 18 | 0.28 | 38 | 0.34 | 54 | 0.44 | 92 |
3 | 18 | 0.29 | 47 | 0.35 | 63 | 0.45 | 102 |
4 | 18 | 0.32 | 59 | 0.38 | 77 | 0.47 | 114 |
7 | 18 | 0.37 | 88 | 0.43 | 109 | 0.56 | 171 |
19 | 18 | 0.58 | 221 | 0.64 | 252 | 0.77 | 340 |
24 | 18 | 0.67 | 273 | 0.73 | 308 | 0.9 | 441 |
30 | 18 | 0.71 | 329 | 0.77 | 366 | 0.94 | 506 |
37 | 18 | 0.76 | 391 | 0.82 | 431 | 0.99 | 579 |
40 | 18 | 0.82 | 427 | 0.88 | 470 | 1.04 | 618 |
61 | 18 | 0.98 | 648 | 1.04 | 698 | 1.21 | 883 |
2 | 16 | 0.32 | 49 | 0.38 | 67 | 0.48 | 108 |
3 | 16 | 0.34 | 62 | 0.4 | 80 | 0.49 | 119 |
4 | 16 | 0.37 | 77 | 0.43 | 98 | 0.55 | 155 |
7 | 16 | 0.43 | 116 | 0.49 | 140 | 0.62 | 209 |
10 | 16 | 0.57 | 176 | 0.63 | 207 | 0.76 | 294 |
14 | 16 | 0.62 | 230 | 0.68 | 263 | 0.8 | 349 |
16 | 16 | 0.65 | 255 | 0.71 | 288 | 0.88 | 418 |
19 | 16 | 0.68 | 303 | 0.74 | 338 | 0.91 | 473 |
24 | 16 | 0.79 | 362 | 0.85 | 402 | 1.02 | 555 |
30 | 16 | 0.88 | 473 | 0.94 | 518 | 1.11 | 686 |
37 | 16 | 0.94 | 558 | 1 | 605 | 1.17 | 782 |
40 | 16 | 1.01 | 606 | 1.07 | 659 | 1.24 | 848 |
61 | 16 | 1.16 | 866 | 1.22 | 928 | 1.39 | 1142 |
7 | 14 | 0.46 | 155 | 0.52 | 182 | 0.65 | 256 |
10 | 14 | 0.61 | 232 | 0.67 | 265 | 0.8 | 357 |
14 | 14 | 0.66 | 305 | 0.72 | 340 | 0.89 | 472 |
16 | 14 | 0.7 | 345 | 0.76 | 380 | 0.93 | 519 |
19 | 14 | 0.73 | 412 | 0.79 | 449 | 0.96 | 593 |
24 | 14 | 0.89 | 527 | 0.95 | 572 | 1.12 | 742 |
30 | 14 | 0.94 | 635 | 1 | 682 | 1.17 | 859 |
37 | 14 | 1.01 | 761 | 1.07 | 814 | 1.24 | 1003 |
40 | 14 | 1.09 | 829 | 1.15 | 885 | 1.32 | 1088 |
61 | 14 | 1.25 | 1195 | 1.31 | 1260 | 1.48 | 1489 |
NOTE—These values are for reference purposes only and should not be construed as requirements. Dimensions are based on the use of Class B conductors. Weights of armored constructions are based on aluminum braid armor. It is recommended that the user/specifier contact the manuf acturer for manufacturer specific values.